Table 4.

Summary Statistics for the Diagnostic Accuracy of 13C-Urea Breath Test.

Sub-groups Number of Studies P-value (I2)a P-value (I2)b Sensitivity (95% CI) Specificity (95% CI)

All studies* 15 <0.01 (72.8%) <0.01 (64.5%) 0.97 (0.96, 0.98) 0.96 (0.95, 0.97)
By dose of 13C-urea**
      50 mg 4 0.24# (28.7%) 0.17# (40.6%) 1.00 (0.98, 1.00) 0.99 (0.96, 1.00)
      75 mg 4 0.01 (76.5%) 0.28# (21.0%) 0.93 (0.90, 0.96) 0.96 (0.94, 0.98)
      100 mg 5 0.07 (53.0%) <0.01 (76.1%) 0.98 (0.97, 0.99) 0.94 (0.92, 0.96)
By cut-off threshold
      <5.0 δ over baseline 9 0.02 (54.4%) <0.01 (75.9%) 0.98 (0.97, 0.99) 0.96 (0.95, 0.97)
      ≥5.0 δ over baseline 6 <0.01 (76.5%) 0.30# (17.3%) 0.94 (0.92, 0.96) 0.97 (0.95, 0.98)
By breath sample collection time
      10 to 15 minutes 5 <0.01 (83.0%) 0.06 (55.4%) 0.96 (0.94, 0.98) 0.94 (0.90, 0.96)
      20 minutes 5 0.26# (24.0%) 0.15# (40.3%) 0.99 (0.98, 1.00) 0.99 (0.97, 1.00)
      30 minutes 5 0.07 (54.6%) 0.10# (48.4%) 0.96 (0.94, 0.97) 0.96 (0.94, 0.98)
By locality***
      Hong Kong 6 <0.01 (75.5%) 0.36# (8.4%) 0.96 (0.94, 0.98) 0.98 (0.96, 0.99)
      Taiwan 5 0.13# (44.0%) 0.06 (54.8%) 0.98 (0.96, 0.99) 0.93 (0.91, 0.96)
By manufacturer
      13C-UBT (INER, Taiwan) 5 0.13# (44.0%) 0.06 (54.8%) 0.98 (0.96, 0.99) 0.93 (0.91, 0.96)
      Others 10 <0.01 (77.5%) 0.05 (46.7%) 0.96 (0.94, 0.97) 0.98 (0.97, 0.99)

* Four articles had data for two sets of samples, tools and findings; a total of 15 studies were obtained.

** One study was not included in this sub-group due to absence of reported 13C-urea amount used, and another study was excluded due to use of multiple amounts in a single study (for different age groups in children).

*** Studies done in Japan, Israel and Singapore were excluded due to having only two or less studies per locality.

a P-value for heterogeneity (chi-squared) and I2 test for heterogeneity quantification for sensitivity analysis.

b P-value for heterogeneity (chi-squared) and I2 test for heterogeneity quantification for specificity analysis.

# P-value is not significant (≥0.1).