Table 4. Comparison of Sensitivity and Specificity of Serum ADAM 8, CEA and Their Combination as Single Markers and/or as a Multiple-Markers Panel for Prediction of GC Determined by Logistic Regression Analysis in Validation Dataset.
Marker panel* | Cut-off values | Sensitivity (%) | Specificity (%) |
---|---|---|---|
ADAM 8 | 30 | 73.7 | 86.2 |
CEA | 5 | 23.1 | 91.4 |
ADAM 8+CEA | 25, 5 | 81.8 | 84.0 |
ADAM 8, a disintegrin and metalloproteinase domain 8; CEA, carcinoembryonic antigen; GC, gastric cancer.
*Each marker was included as a linear term and evaluated as part of a panel of one to two markers in combination.