Skip to main content
. 2019 Jul 26;19:162. doi: 10.1186/s12886-019-1163-5

Table 2.

Meta-regression and subgroup analyses for sensitivity and specificity

Covariate Number of studies Number of eyes Sensitivity (95% CI) P-value Specificity (95% CI) P-value
Ethnicity
 Asian 2 107 0.91 (0.80–1.00) 0.69 0.82 (0.53–1.00) 0.09
 Other races 14 754 0.87 (0.80–0.93) 0.97 (0.95–1.00)
Type of study
 Prospective 5 301 0.93 (0.88–0.98) 0.61 0.99 (0.96–1.00) 0.08
 Retrospective 8 473 0.79 (0.72–0.86) 0.93 (0.87–1.00)
Etiology
 AMD 7 560 0.89 (0.82–0.95) 0.12 0.98 (0.94–1.00) 0.44
 Other ocular diseases 9 301 0.85 (0.76–0.94) 0.97 (0.92–1.00)
Reference standard
 FA 9 549 0.83 (0.76–0.90) < 0.01 0.94 (0.88–1.00) 0.09
 Other reference standards 7 372 0.92 (0.86–0.97) 0.99 (0.97–1.00)
Type of device
 AngioVue 10 426 0.90 (0.86–0.95) 0.09 0.96 (0.91–1.00) 0.66
 other devices 6 435 0.80 (0.72–0.87) 0.98 (0.96–1.00)
Sample size
 ≥ 50 8 690 0.88 (0.81–0.95) 0.12 0.96 (0.91–1.00) 0.57
 < 50 8 171 0.86 (0.77–0.96) 0.99 (0.96–1.00)