Table 1.

Thermodynamic parameters of M-TTR and W79F M-TTR urea-induced unfolding measured with conventional fluorescence and second derivative spectraa.

Parameter Gross fluorescence at 362 nm d2F/dx2 at
325 nm
d2F/dx2 at
348 nm
d2F/dx2 at
364 nm
Gross fluorescence
(ref.26)
M-TTR
ΔGUFH20 (kJ mol−1) 20.7 ± 3.5 21.3 ± 4.0 20.0 ± 8.0 19.7 ± 4.5 20.4 ± 1.5
m (kJ mol−1 M−1) 7.8 ± 1.3 7.1 ± 1.3 7.8 ± 2.9 7.7 ± 1.6 6.9 ± 0.5
Cm (M) 2.8 ± 0.2 3.0 ± 0.3 2.6 ± 0.3 2.5 ± 0.4 3.0 ± 0.1
W79F M-TTR
Parameter Gross fluorescence at 330nm

d 2 F/dx 2 at

324nm

d 2 F/dx 2 at

346nm

d 2 F/dx 2 at

367nm

Gross fluorescence

(ref.26)

ΔGUFH20 (kJ mol−1) 12.9 ± 1.3 12.9 ± 2.8 n.d 21 ± 14 13.0 ± 1.4
m (kJ mol−1 M−1) 4.2 ± 0.4 4.4 ± 0.08 n.d 6.6 ± 4.3 4.3 ± 0.4
Cm (M) 3.1 ± 0.2 3.0 ± 0.1 n.d 3.2 ± 0.2 3.0 ± 0.1

All data are derived from the data shown in Figs 5 and 6, except those of the last column, previously determined26.