Skip to main content
. 2019 Jun 12;294(30):11609–11621. doi: 10.1074/jbc.RA119.009035

Table 1.

SAXS data collection and scattering-derived parameters

ACMSD ACMSD H110A
Data collection
    Beamline SSRL BL4-2 SSRL BL4-2
    Type of experiment SEC-SAXS SEC-SAXS
    Beam defining slits size (mm) 0.3 × 0.3 0.3 × 0.3
    Sample–detector distance (m) 1.7 2.5
    Beam energy (keV) 11.4 10.1
    Beam current (mA) 500 500
    Exposure time per frame (s) 1 1
    Frames per data set 500 500
    Temperature (K) 298 298
    Sample cell size (mm diameter) 1.5 1.5
    Detector Pilatus 3 X 1M Pilatus 3 X 1M
    SEC column Superdex 200 Increase PC3.2/300 Superdex 200 Increase PC3.2/300
    Sample volume (Concentration) 35 μl (4 mg/ml) 50 μl (4 mg/ml)
    Flow rate (ml/min) 0.05 0.05
Guinier analysis
    q × Rg limita 1.3 1.3
    I(0) (cm−1) 0.0612 ± 0.0011 0.0439 ± 0.0012
    Rg (Å) 47.0 ± 1.06 52.2 ± 1.95
P(r) and Porod volume estimation
    Software Primus/GNOM Primus/GNOM
    qmax (Å−1) 0.30 0.15
    I(0) (cm−1), real space 0.0610 ± 0.0010 0.0454 ± 0.0006
    Rg, real space (Å) 48.28 ± 0.98 55.99 ± 0.84
    Dmax (Å) 175 190
    Porod volume (Å3) 195,000 238,000
    Expected mass (kDa) 158.8 158.8
Rigid-body modeling
    Software CORAL CORAL
    qmax (Å−1) 0.3 0.2
    Number of runs 20 20
Ab initio modeling
    Software (ab initio modeling) DAMMIF GASBOR
    Software (averaging) DAMAVER DAMAVER
    qmax (Å−1) 0.18 0.15
    Number of runs 20 20
    Normalized spatial discrepancy (NSD) 0.763 ± 0.038 2.272 ± 0.242

aq = 4πsin(θ)/λ, where 2θ is the scattering angle.