Skip to main content
. 2019 Jul 29;7(7):2325967119855023. doi: 10.1177/2325967119855023

TABLE 2.

Recurrent Instability and Non–Stability Related Complicationsa

Study Year Graft Type Femoral Fixation Patellar Fixation Redislocation, n (%) Resubluxation, n (%) Other Complications
Lind et al12 2016 Gra Pulley Bone tunnel 4 (3.0) 5 (3.8) None
Machado et al13 2017 Gra Suture Suture 1 (0.8) 3 (2.3) 5 residual knee pain, 3 donor site pain, 2 hematoma, 1 superficial infection
Nelitz et al20 2013 Gra Screw Bone tunnel 0 0 1 knee stiffness
Abouelsoud et al1 2015 Quad Suture None 0 5 (3.8) None
Nelitz et al21 2018 Quad Screw None 0 0 1 knee swelling
Deie et al6 2003 SemiT Pulley Suture 0 2 (1.5) None
Kumahashi et al11 2012 SemiT Pulley Screw 0 0 None

aGra, gracilis; Pulley, soft tissue pulley; Quad, quadriceps; Screw, interference screw; SemiT, semitendinosus; Suture, suture anchor.