Lightning impulse breakdown voltage of insulating liquid.

Liquid Types Breakdown Voltage (kV) Breakdown Time (μs)
Positive Negative Positive Negative
Vegetable Liquid 78.2 83.7 10.3 11.9
Nano Vegetable Liquid 83.9 89.9 10.9 12.3
Mineral Liquid 60.8 103.3 8.7 11.1
Nano Mineral Liquid 66.9 111.2 9.2 11.9