Skip to main content
. Author manuscript; available in PMC: 2019 Aug 1.
Published in final edited form as: J Proteome Res. 2018 May 8;17(6):2205–2215. doi: 10.1021/acs.jproteome.8b00165

Figure 6.

Figure 6.

Starting sample amount influences identification rate. The number of identified peptides (top) and proteins (bottom) are reported for each TMT channel. Analysis revealed an ion threshold intensity of 10 000 produced accurate quantitation and was utilized as a filter for the number of identifications per channel.