Table 1.

In vitro properties of the GAF-CaMP2 calcium indicator compared to permanently fluorescent smURFP and GAF-FP proteins.

Properties Proteins
GAF-CaMP2 GAF-CaMP2-sfGFP smURFPa GAF-FPb
apo sat apo sat
Absorbance maximum (nm) 642 (384) 650 (384) 630 (383, 490) 649 (383, 490) 642 * 637 (379)
Excitation maximum (nm) 620 (371) 640 (374) 630 (372, 493) 642 (374, 493) 642 635
Emission maximum (nm) 676 674 676 (514) 674 (514) 670 670
Quantum yield (%) c 1.8 ± 0.2 4.8 ± 0.2 3.3 ± 0.1 6.9 ± 0.5 17.9 ± 0.2 * 7.3
ε (mM−1·cm−1) d 22.2 ± 0.2 29.2 ± 0.3 15.7 ± 0.4 27.5 ± 0.9 180 49.8
Brightness vs. EGFP (%) e 1.2 4.2 1.5 5.6 96 11
pKa 5.16 ± 0.05; 6.99 ± 0.06; ≥9.3 ± 0.3 4.89 ± 0.05; 7.15 ± 0.02; ≥9.1 ± 0.2 5.30 ± 0.02; 7.28 ± 0.02; ≥9.28 ± 0.06 4.89 ± 0.01; 7.60 ± 0.07; ≥9.31 ± 0.09 3.3 * 4.0; 7.8
ΔF/F (%) Purified protein 0 mM Mg 103 ± 33 93 ± 11 NA NA
1 mM Mg 77 ± 16 78 ± 7
HeLa cells non-fluorescent 169 ± 56
Kd (nM) f 0 mM Mg 235 ± 37 (0.88 ± 0.12) 289 ± 29 (1.54 ± 0.22)
1 mM Mg 435 ± 39 (1.48 ± 0.18) 466 ± 50 (1.54 ± 0.23)
Maturation half-time (min) ND ND 28.2 ± 0.7 (sfGFP)
44 ± 2 (GAF-CaMP2)
39 240
Photobleaching half-time (s) g ND 1150 ± 560 ND 1080 ± 560 377 ± 55 * ND

a Data from [13]. Data marked with an asterisk were determined in this paper. NA, not applicable. ND, not determined. b Data from [12]. c QY for form with excitation maximum at 620−642 nm was determined at pH 7.20. miRFP720 was used as the reference standard [5]. d Extinction coefficient for form with absorbance maximum at 630−650 nm was determined relative to the Soret band at 384 nm for GAF-CaMP2 and relative to sfGFP form at 490 nm [29] for GAF-CaMP2-sfGFP. e Brightness was calculated as a product of the quantum yield and extinction coefficient and normalized to the brightness of EGFP that has an extinction coefficient of 56,000 M−1·cm−1 and quantum yield of 0.6 [30]. f Hill coefficient is shown in square brackets. In the absence and in the presence of 1 mM Mg2+ GCaMP6f had Kd values of 371 ± 20 nM (n = 2.4 ± 0.2) and 632 ± 15 nM (n = 2.25 ± 0.06), respectively. g The power of light from a mercury-xenon lamp before the objective lens was 2.23 mW/cm2.