Sensor System Operating Voltage (V) Power Consumption (W) Response Time (sec) Dynamic Range Sensitivity (@ 0.5N) SNR (dB) Device Process
Triboelectric Based Sensing Method [27] Self-Driven (~0 V) <1 m ~100 m ~ 0.2 N to 10 N ~600 mV 45 Low cost and simple
Humidity Based Measurement [16] >5 V ~20 m ~700 m —— Low —— Low cost and complex
Optical Based Sensing Method [12,13] >3 V ~60 m >1000 m —— Low Low Medium cost and complex
This Work Self-Driven (~0 V) ~600 µ 50 m > 50 mN ~800 mV >20 Low cost and simple