Table 2.

Echocardiographic and hemodynamic changes at baseline and after TAVI

Variable T-1 T+1 P-value
Echocardiographic measurements
 Ejection fraction (%) 55.4±12.7 55.6±11.9 0.576
 Peak AoV (m/s) 4.1±0.7 2.1±0.4 <0.0001
 Peak transvalvular gradient (mmHg) 68.2±23.2 17.0±7.9 <0.001
 Mean transvalvular gradient (mmHg) 41.5±15.7 9.5±5.3 <0.001
Hemodynamic measurements
 Systolic blood pressure (mmHg) 130.3±22.9 119.5±15.8 0.005
 Diastolic blood pressure (mmHg) 74.8±14.5 65.0±11.3 <0.001
 Mean arterial pressure (mmHg) 100.1±17.0 89.9±12.1 0.001
 Pulse pressure (mmHg) 55.6±16.1 54.5±12.5 0.64
 Heart rate (bpm) 66.6±13.0 70.3±10.2 0.081
 Stroke volume (mL) 71.9±12.5 75.8±18.1 0.25
 Cardiac output (L/min) 4.7±0.9 5.3±1.1 0.019
 Cardiac index (L/m*1/m2) 2.5±0.6 2.8±0.6 0.023
 Augmentation index (%) 27.7±13.9 17.6±13.6 0.002
 Aortic pulse wave velocity (m/s) 12.1±1.9 11.6±1.6 0.006
 Peripheral vascular resistance (s*mmHg/mL) 1.31±0.3 1.07±0.2 <0.001

Notes: T-1: 1 day before TAVI. T+1: 1 day after TAVI.

Abbreviation: AoV, aortic valve.