Skip to main content
. 2019 Aug 1;32(4):224–241. doi: 10.1089/jamp.2018.1488

Table 3.

Experimentally Measured Mean (Standard Deviation) Temperature and Relative Humidity Values for Design 1 with a 60°C Thermocouple Temperature Operating in Alternating Mode

  20 LPM 30 LPM
Initial_12 cm
 T (C) 26.6 (0.1) 28.7 (0.2)
 RH (%) 61 (0.6) 40 (0.8)

T, temperature.