Skip to main content
. Author manuscript; available in PMC: 2019 Aug 8.
Published in final edited form as: Environ Sci Process Impacts. 2018 Feb 6;20(3):480–492. doi: 10.1039/c7em00594f

Table 2.

Indicator summary statisticsa


cENT qENT HF183



N
Median (SE)
N
Median (SE)
N
Median (SE)
Station [−] [CFU/100 mL] [−] [CCE/100 mL] [−] [Copies/100 mL]

O1 75 <10   (NA) 75 <53   (NA) 75 <105   (NA)
O2 75 <10   (NA) 74 <53   (NA) 75 217   (40.9)
O3 75 <10   (NA) 75 <53   (NA) 75 204   (43.1)
O4 75 <10   (NA) 74 <53   (NA) 75 230   (44.9)
O5 75 <10   (NA) 75 <53   (NA) 75 284   (78.7)
O6 75 20   (5.5) 75 109   (21.7) 75 224   (64.3)
O7 75 <10   (NA) 74 <53   (NA) 75 362   (90.6)
B1 75 <10   (NA) 75 78   (15.4) 75 635   (89.5)
B2 75 10   (4.0) 75 122   (27.7) 75 689   (101.9)
B3 75 <10   (NA) 75 190   (31.6) 75 1530   (303.6)
B4 75 <10   (NA) 75 150   (18.5) 75 1197   (234.8)
B5 75 10   (2.0) 62 232   (38.2) 75 170   (86.6)
B6 75 41   (7.6) 67 357   (86.3) 75 <105   (NA)
B7 75 31   (8.4) 65 457   (84.4) 75 <105   (NA)
Global 1050 <10   (NA) 1016 80   (3.7) 1050 293   (24.3)
a

Interval censored values were assigned the squared mean root of the Interval censored values were assigned the squared mean root of the interval bounds. See Methods for details. SEs are based on 1000 bootstrap samples. Lower N for qENT is due to failing sample processing control procedures.