Table 4. Diagnostic yields of endocytoscopy for early gastric cancer .

Test Endoscopist A Endoscopist B
Results 95 % CI Results 95 % CI
Sensitivity 87.0 % 67.9 – 95.5 91.3 % 73.2 – 97.6
Specificity 80.0 % 58.4 – 91.9 75.0 % 53.1 – 88.8
Accuracy 83.7 % 70.0 – 91.9 83.7 % 70.0 – 91.9

CI, confidence interval.