Skip to main content
. 2019 Aug 2;6:103. doi: 10.3389/fcvm.2019.00103

Figure 7.

Figure 7

LV volume contours drawn by two different expert users on short-axis cine stack. The left ventricular stroke volume was calculated by both users and found to be 128 and 147 ml, respectively. This difference in calculated stroke volume led to a discrepancy in the classification of this MR case potentially affecting patient outcomes.