Skip to main content
. Author manuscript; available in PMC: 2020 Aug 1.
Published in final edited form as: J Biosci Bioeng. 2019 Mar 20;128(2):226–233. doi: 10.1016/j.jbiosc.2019.01.020

Table 1.

Emulsification settings for generation of a range of tunable droplet sizes.

Emulsification Condition 1 2 3 4 5
Diameter (μm) 75 ± 29 101 ± 9 72 ± 9 51 ± 4 33 ± 4
Avg. Droplet Volume (nL) 0.22 0.54 0.2 0.07 0.02
Droplets/min 2.28E6 1.00E6 2.04E6 2.16E6 2.10E6
Aqueous Flow rate (mL/min) 0.5 0.5 0.4 0.15 0.04
Oil Flow rate (mL/min) 3.0 3.0 3.5 4.0 4.5
Wave Frequency (kHz) none 4.0 6.0 6.5 6.3

Droplet diameters are reported as average ± standard deviation.