Table 2.
The testing accuracy for different levels of variation on Wmax, Wmin.
| Variation level | 10% | 30% | 50% |
|---|---|---|---|
| C2C | 76.67 ± 0.76% | 71.90 ± 1.75% | 63.94 ± 1.34% |
| D2D | 74.91 ± 1.09% | 71.60 ± 0.69% | 65.20 ± 1.15% |
| Combined | 75.34 ± 0.94% | 67.20 ± 2.21% | 56.16 ± 1.73% |
Results for cycle-to-cycle (C2C) variation, device-to-device (D2D) variation, and C2C-D2D combined variation are listed. Simulations are repeated for 12 times with each condition, and the testing accuracy is shown as μ±σ, where μ, σ represents the mean value and standard deviation respectively.