Skip to main content
. 2019 Aug 6;13:812. doi: 10.3389/fnins.2019.00812

Table 2.

The testing accuracy for different levels of variation on Wmax, Wmin.

Variation level 10% 30% 50%
C2C 76.67 ± 0.76% 71.90 ± 1.75% 63.94 ± 1.34%
D2D 74.91 ± 1.09% 71.60 ± 0.69% 65.20 ± 1.15%
Combined 75.34 ± 0.94% 67.20 ± 2.21% 56.16 ± 1.73%

Results for cycle-to-cycle (C2C) variation, device-to-device (D2D) variation, and C2C-D2D combined variation are listed. Simulations are repeated for 12 times with each condition, and the testing accuracy is shown as μ±σ, where μ, σ represents the mean value and standard deviation respectively.