Acquisition sequence | ||
Type (e.g. FLAIR, DIR, DTI, fMRI) |
FLAIR | |
Acquisition time | 5:16 | |
Orientation | Axial-oblique | |
Alignment (e.g. anterior commissure/poster commissure line) |
parallel to the sub-callosal line | |
Voxel size | 1×1×3 | |
TR | 8500ms | |
TE | 120ms | |
TI | 2100ms | |
Flip angle | 90 | |
NEX | 1 | |
Field of view | 25.6cm × 19.2cm | |
Matrix size | 256 × 192 | |
Parallel imaging | Yes | No |
Acquisition sequence | ||
If used, parallel imaging method: (e.g. SENSE, GRAPPA) | ||
Cardiac gating | Yes | No |
If used, cardiac gating method: (e.g. PPU or ECG) | ||
Contrast enhancement | Yes | No |
If used, provide name of contrast agent, dose and timing of scan post-contrast administration | ||
Acquisition sequence | ||
Type (e.g. FLAIR, DIR, DTI, fMRI) |
3D GRE | |
Acquisition time | 6:52 | |
Orientation | oblique | |
Alignment (e.g. anterior commissure/poster commissure line) |
parallel to the sub-callosal line | |
Voxel size | 1×1×3 | |
TR | 50ms | |
TE | 6ms | |
TI | / | |
Flip angle | 10 | |
NEX | 1 | |
Field of view | ||
Matrix size | 256 × 192 | |
Parallel imaging | Yes | No |
Acquisition sequence | ||
If used, parallel imaging method: (e.g. SENSE, GRAPPA) |
||
Cardiac gating | Yes | No |
If used, cardiac gating method: (e.g. PPU or ECG) |
||
Contrast enhancement | Yes | No |
If used, provide name of contrast agent, dose and timing of scan post-contrast administration | ||
Acquisition sequence | ||
Type (e.g. FLAIR, DIR, DTI, fMRI) |
3D T1-WI (IR-FSPGR) | |
Acquisition time | 9:18 | |
Orientation | Oblique | |
Alignment (e.g. anterior commissure/poster commissure line) |
anterior commissure/poster commissure line | |
Voxel size | 1×1×3 | |
TR | 6.6ms | |
TE | 2.8ms | |
TI | 900ms | |
Flip angle | 10 | |
NEX | 1 | |
Field of view | 25.6cm × 19.2cm | |
Matrix size | 256 × 256 | |
Parallel imaging | Yes | No |
If used, parallel imaging method: (e.g. SENSE, GRAPPA) |
||
Cardiac gating | Yes | No |
If used, cardiac gating method: (e.g. PPU or ECG) |
||
Contrast enhancement | Yes | No |
If used, provide name of contrast agent, dose and timing of scan post-contrast administration | ||
Acquisition sequence | ||
Other parameters: |