Skip to main content
. 1984 Sep-Oct;89(5):349–373. doi: 10.6028/jres.089.020

Table 3.

Resistance ratios at fixed points.1,2

Run W(AU) W(AG) W(AL) W(ZN) W(SN)
RT no. 80179
1 4.57174066 4.28647159 3.37604256 2.56895487 1.89283568
2 4.57168631 4.28642060 3.37600925 2.56893131 1.89282128
RT no. 18227
1 4.57157254 4.28629894 3.37591813 2.56886467 1.89278068
2 4.57151496 4.28623733 3.37587016 2.56883989 1.89276336
RT no. 18236
1 4.57148343 4.28625191 3.37588957 2.56884678 1.89277435
2 4.57147650 4.28622095 3.37585840 2.56882739 1.89275797
RT no. 18237
1 4.57149741 4.28628074 3.37591249 2.56886121 1.89277637
2 4.57145197 4.28622217 3.37586485 2.56883266 1.89276204
RT no. 8202
1 4.57150591 4.28624231 3.37592544 2.56888096 1.89279537
2 4.57147188 4.28622642 3.37590991 2.56887218 1.89279135
RT no. 8204
1 4.57152289 4.28627237 3.37594233 2.56888153 1.89279772
2 4.57153108 4.28627577 3.37594331 2.56887922 1.89279320
RT no. 8205
1 4.57137553 4.28617237 3.37587835 2.56884607 1.89277446
2 4.57136712 4.28614094 3.37586420 2.56884047 1.89277239
1

Values derived from resistance values given in tables A1a-g.

2

W(FP)= R(FP)/R(0), where R(0) is derived from the mean of the values of R(TP) before and after R(FP).