Skip to main content
. 2019 Jul 26;12(15):2392. doi: 10.3390/ma12152392

Table 3.

Boundary conditions adopted in modelling.

Surface Temperature
[°C]
Surface Resistance [(m2·K)/W] Description
Internal surface of the wall +21 0.13 Heat flow horizontal, simplified *
Internal surface of the floor +21 0.17 Heat flow downwards, simplified *
External (wall and ground) −18 0.04 Simplified *
Internal (wall and floor) +21 0.25 Condensation risk, simplified *
Cut-off planes Adiabatic

* The simplified model means that convective and radiative heat exchange is described by one common surface resistance.