Skip to main content
. 2019 Jul 26;12(15):2392. doi: 10.3390/ma12152392

Table 4.

Models for the averaged thermal transmittance and linear thermal transmittance: (1)—floor on timber joists, (2)—the self-supporting floor.

Dependent Variable:
Averaged Thermal Transmittance Linear Thermal Transmittance
(1) (2) (1) (2)
λ 0.465 *** 0.221 *** −2.688 *** −2.570 ***
l −0.0003 *** −0.001 *** −0.001 *** −0.002 ***
l2 0.00002 *** 0.00003 *** 0.0001 *** 0.0002 ***
w −0.001 *** −0.002 *** −0.002 *** −0.002 ***
f −0.002 *** 0.002 *** −0.014 *** 0.009 ***
λ·w −0.007 *** - - -
λ·f 0.041 *** - 0.224 *** -
l·w - - −0.00002 *** −0.00003 ***
l·f −0.0001 *** −0.0001 *** −0.0004 *** −0.0005 ***
l2·f 0.00000 *** - 0.00002 *** -
Constant 0.242 *** 0.263 *** 0.113 *** 0.090 ***
Observations 100 100 100 100
R2 0.999 0.997 0.998 0.995
Adjusted R2 0.999 0.997 0.998 0.995
Residual Std. Error 0.0002 0.0004 0.001 0.002
F Statistic 12,234.860 *** 4919.966 *** 5098.955 *** 2594.745 ***

Note: *** p < 0.01.