Skip to main content
. 2019 Jul 31;2019:2860810. doi: 10.1155/2019/2860810

Table 2.

Plasma cortisol levels in the adrenal veins measured from repeated samples (t-15, t0) during AVS [M (25-75%)].

Parameter LAV
(range)
RAV
(range)
PV
(range)
LAV/PV RAV/PV Lateralization ratio A
(range)
Cortisol (nmol/l) t-15 5600
(2780-9945)
7860
(4260-11360)
309
(247-457)
18.22
(1.97-40.82)
24.39
(3.44-206.47)
1.69
(1.02-5.14)
Cortisol (nmol/l) t0 3420
(1632-7665)
3920
(1515-9120)
292
(234-391)
10.76
(2.16-88.21)
13.42
(2.01-65.50)
1.51
(1.00-6.22)
P (t-15 vs t0) 0.455 0.035 0.082 0.209 0.654 0.904
Variance ratio
(t0–t-15/t-15)
0.61±0.51 0.64±0.37 0.17±0.16

LAV, left adrenal vein; RAV, right adrenal vein; and PV, peripheral vein. A side-to-side (high-side to low-side) adrenal vein cortisol gradient.