Skip to main content
. 2019 Aug 19;10:3726. doi: 10.1038/s41467-019-11646-3

Table 1.

Functional comparison of endogenous IP3R levels to those in stable-rescued cells

IP3R1 IP3R2 IP3R3
Stable rescue Pool size (%) 63 ± 1 82 ± 1 69 ± 3
EC50 (nM) 213 ± 44 146 ± 8 1664 ± 492
DKO Pool size (%) 71 74 34
EC50 (nM) 331 209 2895

IP3 sensitivity was measured in permeabilized cells with cuvette-based fluorimeter. IP3 sensitive pool size was determined as the percentage of the maximum Ca2+ signal measured at saturating IP3 concentration relative to that at Tg addition (mean ± SEM, N = 37, 28, and 15 runs, respectively, from six independent experiments). EC50 values were determined by fitting sigmoidal, Hill, 3 parameter function on data points of dose-response measurements (N = 74, 55, and 60 points, respectively) For more details, see Supplementary Fig. 1C, D. DKO results are from19. Source data are provided as a Source Data file