Fitting parameters a and b for Cs fits by Eqs. (8) and (9) used in the plots shown in Fig. 3. The values for Kdintare from Puukko et al. (2018).

Fitted Eq. Kdint (m3/kg) a (m3/kg) b (-)
PP219_1 Eq. (8) 0.140 ± 0.006 0.30 ± 0.05
Eq. (9) 0.02 0.119 ± 0.007 0.34 ± 0.06
PP219_2 Eq. (8) 0.110 ± 0.005 0.38 ± 0.04
Eq. (9) 0.02 0.089 ± 0.004 0.46 ± 0.05
PP309 Eq. (8) 0.043 ± 0.002 0.25 ± 0.05
Eq. (9) 0.0027 0.040 ± 0.002 0.27 ± 0.06
PP175 Eq. (8) 0.60 ± 0.03 0.25 ± 0.03
Eq. (9) 0.0045 0.55 ± 0.03 0.25 ± 0.03
KR56 Eq. (8) 0.102 ± 0.006 0.43 ± 0.03
Eq. (9) 0.0007 0.101 ± 0.006 0.43 ± 0.03
Biotite, 1×10−4 M Eq. (8) 0.058 ± 0.004 0.21 ± 0.03
Biotite, 1×10−5 M Eq. (8) 0.268 ± 0.009 0.130 ± 0.013
Biotite, 1×10−6 M Eq. (8) 0.38 ± 0.02 0.043 ± 0.03