Skip to main content
. 2019 Oct 15;200:363–372. doi: 10.1016/j.neuroimage.2019.07.002

Table 3.

Results from the multiple comparison analysis (mean CBF, CBF intrasession variance, CBF-SNR). MANUAL ICA = manual ICA-based denoising; FIX ICA = automated ICA-based denoising.

Comparison CBF
CBF variance
CBF-SNR
Mean Difference 95% CI Summary Mean Difference 95% CI Summary Mean Difference 95% CI Summary
Raw vs. ENABLE −2.1 −4.0 to −0.2 * −1.6 −4.6 to 1.3 ns −0.2 −0.3 to −0.1 ***
Raw vs. aCompCor −3.2 −3.9 to −2.4 **** 9.0 6.2 to 11.8 **** −0.8 −0.9 to −0.7 ****
raw vs. MANUAL ICA −5.1 −6.1 to −4.2 **** 14.7 10.4 to 18.9 **** −1.8 −2.1 to −1.5 ****
raw vs. FIX ICA −5.0 −5.9 to −4.1 **** 14.1 9.8 to 18.4 **** −1.7 −2.0 to −1.5 ****
ENABLE vs. aCompCor −1.1 −3.1 to 1.0 ns 10.7 6.7 to 14.6 **** −0.7 −0.8 to −0.5 ****
ENABLE vs. MANUAL ICA −3.0 −4.6 to −1.5 **** 16.3 11.1 to 21.5 **** −1.6 −1.9 to −1.4 ****
ENABLE vs. FIX ICA −2.9 −4.4 to −1.4 **** 15.8 10.6 to 21.0 **** −1.6 −1.8 to −1.3 ****
aCompCor vs. MANUAL ICA −2.0 −3.3 to −0.7 *** 5.7 2.2 to 9.1 *** −1.0 −1.2 to −0.7 ****
aCompCor vs. FIX ICA −1.8 −3.0 to −0.6 ** 5.1 1.6 to 8.6 ** −0.9 −1.2 to −0.6 ****
MANUAL ICA vs. FIX ICA 0.2 −0.1 to 0.4 ns −0.5 −1.3 to 0.2 ns 0.08 −0.02 to 0.1 ns