Table 3.
Mean postoperative uncorrected binocular visual acuity results (logMAR) of previous studies on different trifocal intraocular lens models
First Author | IOL Studied | Patients included | Mean postoperative uncorrected binocular visual acuity (logMAR) | ||
---|---|---|---|---|---|
UDVA | UIVA (distance) | UNVA (distance) | |||
Lawless et al. [7] | PanOptix | 33 patients | 0.01 ± 0.10 | 0.30 ± 0.14 (60 cm) | 0.18 ± 0.10 (40 cm) |
Bilbao-Calabuig et al. [4] | AT Lisa tri 839MP | 2141 patients | 0.04 ± 0.08 | 0.00 ± 0.17 (80 cm) | 0.07 ± 0.10 (40 cm) |
Bilbao-Calabuig et al. [4] | Micro F | 2901 patients | 0.06 ± 0.08 | −0.01 ± 0.15 (80 cm) | 0.08 ± 0.10 (40 cm) |
Sheppard et al. [22, 23] | FineVision | 15 patients | 0.19 ± 0.09 | – | – |
Alio et al. [5] | FineVision | 20 patients | 0.18 ± 0.13 | 0.20 ± 0.11 (80 cm) | 0.26 ± 0.15 (40 cm) |
Mojzis et al. [24, 22] | AT Lisa tri 839MP | 30 patients | −0.03 ± 0.09 | 0.08 ± 0.10 (66 cm) | 0.20 ± 0.12 (33 cm) |
Mendicute et al. [8] | AT Lisa tri 839MP | 104 patients | 0.03 ± 0.09 | 0.10 ± 0.15 (80 cm) | 0.15 ± 0.14 (40 cm) |
Cochener et al. [6] | FineVision | 99 patients | 0.01 ± 0.06 | 0.08 ± 0.10 (60 cm) | 0.00 ± 0.04 (30 cm) |
Kretz et al. [25, 21] | AT Lisa tri 839MP | 50 patients | 0.06 ± 0.10 | 0.09 ± 0.10 (66 cm) | 0.06 ± 0.05 (40 cm) |
Jonker SM et al. [23, 25] | Micro F | 15 patients | 0.01 ± 0.11 | 0.32 ± 0.15 (70 cm) | 0.15 ± 0.13 (40 cm) |