Skip to main content
. 2019 Aug 29;21:54. doi: 10.1186/s12968-019-0568-x

Table 3.

Results for diagnostic performance of different measurement approaches

Cut off AUC Sensitivity (%) Specifity (%) PPV (%) NPV (%) Accuracy (%)
Native T1 (ms)
 Global > 980 0.903 85 90 93 79 87
 mSAX > 985 0.850 76 93 95 72 83
 ConSept > 999 0.783 65 97 97 62 77
 Remote > 980 0.841 73 90 91 69 80
ECV (%)
 Global > 31 0.731 47 88 87 49 62
 mSAX > 28 0.717 67 72 81 56 69
 ConSept > 27 0.633 70 52 71 50 63
 Remote > 29 0.685 64 68 76 55 66
T2 (ms)
 Global > 54 0.847 80 87 90 74 82
 mSAX > 53 0.831 78 87 90 72 81
 ConSept > 53 0.820 80 87 90 74 82
 Remote > 54 0.799 74 87 89 70 79

ECV extracellular volume fraction, mSAX midventricular short axis, NPV negative predictive value, PPV positive predictive value