Skip to main content
. Author manuscript; available in PMC: 2019 Aug 29.
Published in final edited form as: Dig Dis Sci. 2018 Feb 3;63(4):856–859. doi: 10.1007/s10620-018-4947-1

Table:

Association between colonoscopy position and adenoma detection, polyp detection, and withdrawal time

Colonoscopy position (nth colonoscopy of the day) Number of colonoscopies Adenoma Detection Rate (%, 195% CI) Polyp detection rate
(%, 95% CI)
Wthdrawal time* (minutes, 95% CI) Adenoma Detection Rate adjusted for patient characteristics (%, 95% CI)
1 20,348 29.5 (28.9–30.1) 49.9 (49.2–50.6) 11.6 (11.4–11.9) 29.8 (29.1–30.4)
2 16,885 30.2 (29.5–30.8) 50.2 (49.4–50.9) 11.4 (11.2–11.7) 30.1 (29.4–30.8)
3 13,898 30.0 (29.2–30.7) 50.0 (49.2–50.8) 11.1 (10.9–11.4) 29.8 (29.0–30.5)
4 11,037 30.2 (29.3–31.0) 49.1 (48.2–50.0) 11.2 (10.9–11.5) 29.8 (28.9–30.6)
5 8,111 30.8 (29.8–31.8) 48.6 (47.5–49.7) 10.8 (10.5–11.1) 30.2 (29.2–31.2)
6 5,765 30.3 (29.1–31.5) 47.3 (46.0–48.6) 10.2 (9.8–10.6) 29.7 (28.6–30.9)
7 3,851 30.5 (29.1–32.0) 46.5 (45.0–48.1) 9.7 (9.3–10.1) 30.7 (29.2–32.1)
8 2,520 27.7 (26.0–29.5) 45.0 (43.1–46.9) 9.7 (9.2–10.3) 28.0 (26.2–29.8)
9 1,647 27.4 (25.3–29.6) 44.9 (42.5–47.3) 9.6 (8.9–10.3) 28.2 (26.0–30.5)
10+ 2,562 27.5 (25.7–29.2) 43.4 (41.5–45.4) 9.3 (8.6–9.9) 28.5 (26.7–30.3)
*

Data on withdrawal time were only available at one site and available for 12,637 colonoscopies.