Skip to main content
. Author manuscript; available in PMC: 2020 Oct 1.
Published in final edited form as: Environ Res. 2019 Aug 2;177:108618. doi: 10.1016/j.envres.2019.108618

Table 4.

Effectiveness of ZeroWater® filters to remove arsenic and lead.

EPA standard (ppb) Pre-Filtration Concentration (ppb) Post-Filtration Concentration (ppb) % Removal Average % Removal
Arsenic 10 21.39 0.06 99.73 98.98
10.33 0.11 98.92
13.93 0.01 99.96
13.64 0.37 97.30
Lead 15 66.30 0.10 99.85 99.37
21.26 0.24 98.89