Skip to main content
. 2019 Aug 28;13:1635–1640. doi: 10.2147/OPTH.S213448

Table 1.

The mean and standard deviation of PRVEP before and after the treatment of panretinal photocoagulation (PRP)

Visual evoked potential components Session Study Group P-value
P100 Amplitude (µv) Pre 9.30±1.34 <0.001
First 8.61±1.35 <0.001
Second 8.09±1.44 <0.001
Third 7.59±1.54 <0.001
1.5 months 8.05±1.37 <0.001
P100 Latency (ms) Pre 108.40±6.45 <0.001
First 111.24±5.82 <0.001
Second 114.14±5.74 <0.001
Third 117.87±6.42 <0.001
1.5 months 115.89±6.49 <0.001