Table 1.

Panel passing rate (PPR)* for different respirator families and evaluation criteria.

Respirator Family Test Criterion,,§ Subjects (n) FFo ≥ 500 (PPR %) FFo ≥ 1,000 (PPR %) FFo ≥ 2,000 (PPR %)
Three-Size Family Criterion 1 24 100 96 96
Criterion 2 25 96 96 92
Criterion 3 24 96 92 92
Two-size family Criterion 1 24 79 75 63
Criterion 2 25 76 72 60
Criterion 3 24 63 38 29
One-size family Criterion 1 24 88 79 76
Criterion 2 25 64 52 52
Criterion 3 24 54 38 33
*

PPR is the panel passing rate for the number of subjects tested.

Criterion 1: Achieve FFo ≥ 500 on at least one of the two donnings.

Criterion 2: Achieve FFo ≥ 500 on the first donning only; the second donning was not evaluated for this analysis.

§

Criterion 3: Achieve a FFo ≥ 500 for both of the two donnings.