Skip to main content
. 2019 Aug 15;12(16):2595. doi: 10.3390/ma12162595

Table 5.

LCA results for each sub-stage of the “product stage” (A1–A3) of one default thermal insulation tile for flat roofs.

Category Indicator Unit Life Cycle Stages (Total per Default Thermal Insulation Tile)
A1–A3 A1 A2 A3.1 A3.2 A3.3
PE-NRe MJ 6.98E + 01 6.01E + 01 1.29E + 00 3.38E + 00 1.86E + 00 3.20E + 00
PE-Re MJ 1.32E + 01 1.72E + 00 1.72E − 03 9.56E + 00 5.55E − 01 1.33E + 00
ADP kg Sb eq 2.78E − 06 2.03E − 06 3.63E − 09 4.32E − 07 5.64E − 08 2.59E − 07
ADP (f.f.) MJ 6.38E + 01 5.46E + 01 1.28E + 00 3.15E + 00 1.67E + 00 3.05E + 00
GWP kg CO2 eq 5.51E + 00 4.80E + 00 9.11E − 02 1.56E − 01 1.40E − 01 3.20E − 01
ODP kg CFC-11 eq 1.85E − 07 1.49E − 07 1.85E − 10 1.41E − 08 1.06E − 08 1.11E − 08
POCP kg C2H4 eq 1.24E − 03 9.70E − 04 2.91E − 05 8.60E − 05 3.92E − 05 1.20E − 04
AP kg SO2 eq 1.65E − 02 1.24E − 02 4.09E − 04 8.08E − 04 9.86E − 04 1.88E − 03
EP kg PO43− eq 3.81E − 03 2.85E − 03 9.35E − 05 2.44E − 04 1.67E − 04 4.56E − 04