Skip to main content
. 2019 Aug 10;19(16):3502. doi: 10.3390/s19163502

Table 1.

Library Screening Results.

Donor (Terminus) Acceptor (Terminus) Fold-Change in Ratio
FRET BRET
NanoLuc (C) mScarlet (N) na 5.12 ± 0.18
NanoLuc (C) tdTomato (N) na 4.83 ± 0.20
NanoLuc (C) GRvT (N) na 4.56 ± 0.29
NanoLuc (N) mScarlet (C) na 1.07 ± 0.21
NanoLuc (N) tdTomato (C) na - *
NanoLuc (N) GRvT (C) na - *
GeNL 1 (C) mScarlet (N) 1.53 ± 0.01 1.90 ± 0.02
GeNL (C) tdTomato (N) - * - *
GeNL (C) RRvT (N) 1.39 ± 0.01 2.04 ± 0.01
CeNL 2 (C) mScarlet (N) 1.88 ± 0.01 1.96 ± 0.01
CeNL (C) tdTomato (N) - * - *
CeNL (C) RRvT (N) 1.50 ± 0.01 2.07 ± 0.02
CeNL (C) mNeonGreen (N) 1.86 ± 0.06 1.25 ± 0.02

Not applicable to BRET-only sensors. * Poor or no expression. 1 GeNL is mNeonGreen-NanoLuc. 2 CeNL is mTurquoise2-NanoLuc. BRET: bioluminescence resonance energy transfer; FRET: Förster-type resonance energy transfer.