Comparison of pharmacology for test compounds in the GluA1o-γ4 intracellular calcium assays. Data are expressed as the mean ± standard deviation of n = 3 individual concentration-response experiments.

Name Type GCaMP6s pEC50 Fluo-4 pEC50
kainate agonist 5.84 ± 0.16 6.10 ± 0.09
glutamate agonist 5.41 ± 0.03 6.27 ± 0.03
domoate agonist 7.00 ± 0.12 7.34 ± 0.11
(S)-AMPA agonist 6.26 ± 0.03 6.99 ± 0.14
(R)-AMPA agonist 5.11 ± 0.13 5.81 ± 0.12
cyclothiazide PAM 5.31 ± 0.05 5.02 ± 0.25
LY395153 PAM 7.08 ± 0.04 6.99 ± 0.26
GCaMP6s pIC 50 Fluo-4 pIC 50
CP-465022 antagonist 6.73 ± 0.33 6.77 ± 0.15
perampanel antagonist 7.10 ± 0.14 7.04 ± 0.10
talampanel antagonist 6.02 ± 0.27 5.65 ± 0.08
NBQX antagonist 6.14 ± 0.25 5.18 ± 0.06
GYKI53655 antagonist 6.16 ± 0.10 6.00 ± 0.13