Skip to main content
. Author manuscript; available in PMC: 2020 Sep 1.
Published in final edited form as: Pediatr Crit Care Med. 2019 Sep;20(9):832–840. doi: 10.1097/PCC.0000000000002011

Table 4.

Adjusted Model for Nurse Preparednessa

Variable Beta Coefficient (95% CI) Standard Error p-value
 Handoff Mode; Telemedicine 0.34 (0.07–0.61) 0.13 0.02
 Survey Recall Time −0.01 (−0.05–0.02) 0.02 0.37
 PRISM III Score 0.006 (−0.05–0.06) 0.02 0.81
 Intercept 3.07 (2.86–3.30) 0.10 <0.001
a

Linear multi-level model with nurse as a random intercept and nurse preparedness as the outcome. This model excludes patients with missing PRISM III scores and reflects the same patients in Table 2.