Skip to main content
. 2019 May 29;59(9):3002–3025. doi: 10.1111/trf.15344

Table 2.

Loss of PLT collections due to guard band failure

Collections (n) 2016 2017 2018 Total
Jan* ‐Mar Apr ‐ Jun Jul ‐Sep Oct ‐ Dec Jan ‐ Mar Apr ‐ Jun Jul ‐Sep Oct ‐ Dec Jan ‐ Mar Apr ‐ Jun Jul ‐Sep Oct ‐ Dec
Overall 463 564 579 544 542 565 610 565 484 536 501 516 6468
Outside guard bands 34 26 28 16 19 20 16 14 14 10 5 7 209
Failure rate (%) 7.3 4.6 4.8 2.9 3.5 3.5 2.6 2.5 2.9 1.9 1.0 1.4 3.2
PLT retention 93% ± 1.2% (n = 828) 94% ± 1.5% (n = 794) 91% ± 1.4% (n = 966) NA
*

beginning January 11, 2016. A collection with high platelet yield can be split and result in 2 transfusions, often in different patients.

Failure to meet the guard band of the Dual Storage kits: loss of successful platelet collections (%).

Retention rate of platelets after the PRT process (mean ± standard deviation; number of PRT platelet products tested for quality assurance to document the loss of platelets) n/a − not applicable.