Table 1.
Nonlinear optical coefficients of biological synthesized tellurium
Laser | Sample | T (%) | α0 (cm−1) | Isat (GW·cm−2) | Imχ(3) (×10−14esu) | FOM (×10−15 esu·cm) |
---|---|---|---|---|---|---|
515 nm, 340 fs | Bio-Te-PmPV | 54.0 | 6.17 | 201 ± 35 | −1.07 ± 0.11 | 1.74 ± 0.18 |
Graphene-NMP | 46.1 | 7.74 | 364 ± 57 | −0.67 ± 0.09 | 0.86 ± 0.11 | |
800 nm, 100 fs | Bio-Te-PmPV | 45.0 | 7.99 | 261 ± 176 | −1.2 ± 0.4 | 1.47 ± 0.52 |
Graphene-NMP | 16.5 | 18.0 | 910 | −0.968 | 0.54 | |
1030 nm, 340 fs | Bio-Te-PmPV | 52.4 | 6.47 | 145 ± 23 | −2.76 ± 0.58 | 4.27 ± 0.91 |
Graphene-NMP | 52.9 | 6.37 | 56 ± 11 | −5.9 ± 2.1 | 9.3 ± 3.2 | |
2500 nm, 35 fs | Bio-Te-PMMA | 74.2 | 25.7 | 220 | −20.5 | 7.99 |
Graphene-PMMA | 75.7 | 78.9 | 900 | −15.4 | 1.95 | |
2800 nm, 35 fs | Bio-Te-PMMA | 29.6 | 105 | 245 | −84.1 | 8.03 |
Graphene-PMMA | 71.2 | 96.2 | – | – | – |
Saturable absorption coefficients, Isat, of Bio-Te and graphene obtained from open-aperture z-scan experiments under various femtosecond laser irradiations, noting that the graphene does not show saturable absorption at 2.8 μm