Table 1.
Frost-point temperature °C | Estimated maximum uncertainties in moisture content due to estimated uncertainties in: | ||||
---|---|---|---|---|---|
Temperature measurement percent | Pressure measurement percent | Vapor pressure equation percent | Nonideal gas correction percent | Total percent | |
−30 | 0.31 | 0.2 | 0.07 | 0.30 | 0.88 |
−35 | .32 | .2 | .08 | .45 | 1.05 |
−40 | .34 | .2 | .10 | .60 | 1.24 |
−45 | .36 | .2 | .12 | .80 | 1.48 |
−50 | .37 | .2 | .14 | 1.00 | 1.71 |
−55 | .39 | .2 | .16 | 1.50 | 2.25 |
−60 | .41 | .2 | .19 | 2.00 | 2.80 |
−65 | .43 | .2 | .22 | 2.50 | 3.35 |
−70 | .45 | .2 | .25 | 3.00 | 3.90 |
−75 | .47 | .2 | .29 | 3.50 | 4.46 |
−80 | .49 | .2 | .33 | 4.00 | 5.02 |
−85 | .52 | .2 | .38 | 4.50 | 5.60 |
−90 | .55 | .2 | .43 | 5.00 | 6.18 |
−95 | .58 | .2 | .48 | 5.50 | 6.76 |
−100 | .61 | .2 | .54 | 6.00 | 7.35 |