Skip to main content
. 2019 Aug 13;1:100030. doi: 10.1016/j.ijpx.2019.100030

Table 2.

The limit of quantification and the limit of detection for the three different HPLC assays to quantify the concentration of each of the CPPs.

Limit of quantification (LoQ) µg/mL Limit of detection (LoD) µg/mL
RRH 5.4 1.8
TAT 3.1 1.0
bTAT 2.7 0.9