Skip to main content
. 2019 Sep 1;11(1):e2019055. doi: 10.4084/MJHID.2019.055

Table 3.

The performance of different laboratory markers in EOS diagnosis.

Parameters AUC Cutt of value Sensitivity % Specificity % LR+ PPV % NPV %
Group 1 Group 2 Group 1 Group 2 Group 1 Group 2 Group 1 Group 2 Group 1 Group 2 Group 1 Group 2 Group 1 Group 2
PLR 0.812 0.847 39.5 57.7 88.9 91.3 94.7 97.6 16 9.2 94.3 97.4 88.6 91.8
CRP (mg/L) 0.88 0.913 4.5 7.2 72.7 87.9 69.1 71.3 4.7 8.3 70.1 75.3 71.6 86.5
PCT (ng/ml) 0.827 0.865 0.8 2.2 69.4 83.4 96.3 98.8 11.2 19.3 94.9 98.5 75.8 85.6
I/T ratio 0.947 0.955 0.18 0.22 45.6 54.3 96.7 98.1 16.3 12.5 93.2 96.6 30.1 68.2

Group 1: Suspected Early Onset Neonatal Sepsis; Group 2: Proven Early Onset Neonatal Sepsis; PLR, platelet to lymphocyte ratio; CRP, C-reactive protein; PCT, Procalcitonin; I/T, immature to total neutrophil; LR+, Likelihood Ratio; PPV, Positive predictive value; NPV, Negative predictive value.