Abstract
Background
Intra-articular (IA) injection of hyaluronic acid (HA) (IA-HA) is a well-recognized treatment option for pain associated with symptomatic knee osteoarthritis (OA). IA-HA products differ in their HA content, molecular weight, cross-linking, and source of HA. These differences are assumed to affect the biocompatibility of the IA-HA products once injected inside the knee joint.
Methods
In the present study, we investigated the biocompatibility of three multiple-injection IA-HA products available in the global market. These included SUPARTZ FX™, a medium range molecular weight HA derived from rooster comb (Avian-HA); ORTHOVISC®, a high range molecular weight HA obtained through biological fermentation (Bio-HA); and SYNVISC®, a high molecular weight cross-linked hyaluronan derived from rooster comb (Avian-CL-HA). Rabbit knee joint tissues were histologically and biochemically examined after IA injection of the products. Furthermore, we compared the amounts of impurities in the IA-HA products.
Results
IA injection of Avian-CL-HA into rabbit knee joints induced the aggregation of inflammatory cells, infiltration of eosinophils, and an increase in the number of cells in the synovial fluid. However, these effects were not seen in the Avian-HA and Bio-HA groups. The residual protein content and the contaminant levels of bacterial endotoxins were below the limit of quantitation in all HA products. Avian-CL-HA contained relatively a large amount of (1 → 3)-β-D-glucan, but this was below the lower limit of quantification in the other HA products.
Conclusions
The present results clearly demonstrate that the biocompatibility of Avian-HA is comparable to that of Bio-HA, and they were both considered to have a favorable safety profile for the treatment of symptomatic OA of the knee. However, immunostimulatory activity was observed after injection of Avian-CL-HA: this might be a result of its unique cross-linking structure and/or the considerable amount of (1 → 3)-β-D-glucan impurity present in the formulation.
Keywords: Hyaluronan, Avian, Fermentation, Biocompatibility, (1 → 3)-β-D-glucan
Background
Knee osteoarthritis (OA) is a major common joint disorder that is predicted to become even more prevalent with population ageing [1, 2]. OA is characterized by progressive deterioration of the articular cartilage and a decrease in the rheological behavior of the synovial fluid, which includes a reduction in the molecular weight and concentration of hyaluronic acid (HA), causing decreased elasticity and viscosity of the synovial HA matrix [3, 4]. Intra-articular (IA) injection of HA is a widely used treatment option for pain associated with symptomatic knee OA [5–7]. In the knee joint, HA plays an important role in the lubrication of the joints under both dynamic and static conditions, and in exerting various physiological effects, such as decrease in pro-inflammatory cytokine levels for mitigating cartilage degeneration and reduction of COX-2 production for reducing pain sensation [8–10]. Therefore, it is recognized that IA-HA is a beneficial treatment for OA.
IA-HA products are currently characterized by various properties, including their HA content, molecular weight, cross-linking, and the source of HA. The four major types of HA products are defined by HA source and cross-linking. Our study is focused on three of the multiple-injection products available: SUPARTZ FX™ and SYNVISC® are avian-based products, whereas ORTHOVISC® is produced by bacterial fermentation. In addition, SYNVISC® is cross-linked, whereas SUPARTZ FX™ and ORTHOVISC® are not. SYNVISC® has a unique structure linked via protein and divinyl sulfone (DVS) [11]. All these products are generally well tolerated, and the most common side effects are injection site pain, swelling and/or fluid buildup around the knee. These reactions are typically mild and resolved without treatment.
Rare cases of severe side effects caused by IA-HA are recognized as pseudoseptic reactions. It has been suggested that the unique cross-linked structure of SYNVISC® may be associated with an increased incidence of these reactions [12–14]. The development of pseudoseptic reactions has been reported in patients receiving repeated injections of SYNVISC® [15, 16]; however, it has not been reported that the other avian-derived products induce clear symptom characterized as pseudoseptic reactions so far. On the other hand, Altman et al. reported that patients using biological fermentation-derived HA had fewer cases of acute flare-ups at the injection site than those using avian-derived HA products [17]. These reports have led to confusion as to whether the severe reactions are associated with the source of HA or the existence of a cross-linked structure.
To assist in the understanding of the safety characteristics of IA-HA products, we studied the biocompatibility of three HA products, including Avian-HA (SUPARTZ FX™), Bio-HA (ORTHOVISC®), and Avian-CL-HA (SYNVISC®), in normal rabbit knee joints and compared the amount of impurities in the three products.
Methods
Materials
SUPARTZ FX™ was purchased from Seikagaku Corporation (Tokyo, Japan). ORTHOVISC® was from Anika Therapeutics, Inc. (Bedford, MA). SYNVISC® was from Sanofi K.K. (Tokyo, Japan). Details of these products are given in Table 1. Water for Injection (WFI) and saline (Otsuka Normal Saline) was from Otsuka Pharmaceutical Factory, Inc. (Tokushima, Japan). The Glucatell® and Pyrochrome® plus Glucashield® kits were from Associates of Cape Cod, Inc. (Falmouth, MA), and used for (1 → 3)-β-D-glucan and endotoxin detection, respectively. The DC (detergent compatible) protein assay kit II was from Bio-Rad Laboratories, Inc. (Hercules, CA), and was used for protein detection in each HA product. The Pierce™ BCA Protein Assay kit was from Thermo Fisher Scientific (Waltham, MA), and was used for protein detection in synovial fluid in the biocompatibility study. Endo (1 → 3)-β-D-glucanase was prepared according to the method of Tanaka et al. [18].
Table 1.
Brand name (Lot number) | Type | Concentration | Origin | Molecular weighta |
---|---|---|---|---|
SUPARTZ FX™ (4X7Z01) | Natural HA | 10 mg/mL (2.5 mL) | Avian | 620–1170 kDa |
ORTHOVISC® (N170038B) | Natural HA | 15 mg/mL (2 mL) | Fermentation | 1000–2900 kDa |
SYNVISC® (6RSP017) | Cross-linked HA (protein and DVS)b | 8 mg/mL (2 mL) | Avian | hylan A; 6000 kDa hylan B; > 6000 kDa |
aMolecular weight supplied by the manufacturer
bHylan A has protein-mediated cross-linking, hylan B is composed of hylan A with additional DVS-mediated cross-linking
Animals
Male New Zealand White rabbits (12 weeks old) were purchased from Oriental Yeast Co., Ltd. (Tokyo, Japan). The animals were housed under specific pathogen-free conditions at a room temperature between 20 °C and 26 °C, and humidity of approximately 50% on a 12-h/12-h light/dark cycle. The animals were quarantined and acclimatized for 1 week before dosing. The animal studies were reviewed and approved by the Institutional Animal Care and Use Committee of Seikagaku Corporation (approval number, 72–306) and performed under the animal husbandry/management system in an appropriate environment with animal protection/welfare in mind.
Biocompatibility study in normal rabbit knee joints
A biocompatibility study was conducted in accordance with our previous study [19]. Twenty-one rabbits were divided into four groups (n = 6 or 3) based on body weight and anesthetized with an intravenous injection of mixed anesthesia containing midazolam (Dormicum, Astellas Pharma Inc., Tokyo, Japan), xylazine (Selactar 2%, Bayer Yakuhin Ltd., Osaka, Japan), butorphanol (Vetorphale, Meiji Seika Pharma Co., Ltd., Tokyo, Japan), and saline (1:2:1:2), in a volume of 2 mL/animal. The animals received three consecutive weekly intra-articular injections of 0.25 mL of either saline, Avian-HA, Bio-HA, or Avian-CL-HA into both knee joints. All the rabbits were euthanized by exsanguination under deep anesthesia induced with the above-mentioned mixed anesthesia intravenous injection at 15 days after the first injection. Both knee joints were collected. Synovial lavage fluid was collected from the right knee joint by washing the joint cavity three times with 0.5 mL washing buffer (1 mM ethylenediaminetetraacetic acid in phosphate-buffered saline). The total number of cells in the synovial fluid was counted using a light microscope. For characterization of the cell types (monocytes, lymphocytes, and heterophils), the synovial fluid was smeared on a slide, stained with Diff-Quick (Sysmex Corporation, Hyogo, Japan), and then observed with a light microscope. The total protein content in synovial fluid was measured using the Pierce™ BCA Protein Assay kit. The synovium was collected from the left knee joint and was fixed in 10% neutral buffered formalin. Fixed samples were processed, embedded in paraffin, sectioned, and stained with hematoxylin and eosin (H&E) for histological examination. Blinded histological scoring was performed independently by two investigators. Inflammatory reaction with eosinophil infiltration was scored on a 4-point scale, from Grade 0 (no change) to Grade 3 (severe change). Synovial thickening was scored using criteria given in a previous report [19] (Table 2). The numbers of evaluated samples were n = 6 per each group except for the saline group, which was n = 3.
Table 2.
Histological findings | Score | |
---|---|---|
Synovial thickening | Lining cell layer 1–2 cells thick | 0 |
Lining cell layer 3–5 cells thick | 1 | |
Lining cell layer 6–8 cells thick and/ or mild increase in cellularity | 2 | |
Lining cell layer > 9 cells thick and/ or severe increase in cellularity | 3 | |
Inflammatory cell infiltration | None | 0 |
Slight | 1 | |
Moderate | 2 | |
Severe | 3 |
Determination of protein levels
The protein level in each HA product was determined by the DC protein assay kit II according to the manufacturer’s instructions. Each HA product was diluted two-fold with purified water and incubated with the attached assay reagent for a minimum of 15 min at room temperature. The absorbance of the reaction mixture was measured in triplicate at 750 nm with a spectrophotometer (UV-1700; Shimadzu Corporation, Kyoto, Japan). The protein concentration range for the standard curve was 5–125 μg/mL. The sensitivity of the assay is defined as the lowest concentration used in the standard curve. To determine protein recovery, each HA product was spiked with a known amount of bovine serum albumin (BSA) and assayed, and the recovery rate was calculated.
Bacterial endotoxin test
Bacterial endotoxin levels were determined using the kinetic chromogenic Limulus Amoebocyte Lysate (LAL) assay (Pyrochrome® reconstituted with Glucashield® buffer). Avian-HA was diluted twice with Water for Injection. Bio-HA and Avian-CL-HA were diluted 10 times in the same manner. Briefly, 50 μL of test substance was transferred to each well of a 96-well microtiter plate, and the lysate test solution was added at 50 μL/well. The optical density was read at 405 nm in a plate reader (Wellreader MP-96; Seikagaku Corp., Tokyo, Japan). The endotoxin concentration range for the standard curve was 0.005–0.5 EU/mL. The sensitivity of the assay is defined as the lowest concentration used in the standard curve. To determine endotoxin recovery, each HA product was spiked with a known amount of endotoxin and assayed, and the recovery rate was calculated.
Determination of (1 → 3)-β-D-glucan levels
(1 → 3)-β-D-glucan levels were determined using the Glucatell® kit according to manufacturer’s instructions. Avian-HA, Bio-HA and Avian-CL-HA were diluted 10-, 30-, and 300-fold, respectively, with water certified free of interfering glucan. The Glucatell/sample mixture was incubated at 37 °C ± 1 °C in a microplate reader (ELx808IU, BioTek Instruments, Inc., Winooski, VT) equipped with a 405 nm filter and analyzed over time. The (1 → 3)-β-D-glucan concentration range for the standard curve was 3.125–50 pg/mL. The limit of quantitation for (1 → 3)-β-D-glucan was 1.8 pg/mL (lower limit of quantitation) and 50 pg/mL (upper limit of quantitation). To determine (1 → 3)-β-D-glucan recovery, each HA product was spiked with a known amount of (1 → 3)-β-D-glucan and assayed, and recovery rate was calculated. The kit contains highly purified (1 → 3)-β-D-glucan derived from pachyman (from Poria cocos) as a standard substance.
Statistical analyses
All statistical analyses were performed using the Statistical Analysis System (SAS Institute Inc., Cary, NC). Parametric Tukey’s test was used for the protein contents and cell numbers in synovial lavage fluid and histological scores. The significance level was set at 5% (two-tailed). Data were represented as the mean and standard error of the mean (SE). For spike and recovery analysis, recovery rate (%) was calculated by dividing the measured value by the spiked value after subtracting any baseline signal from the measured sample.
Results
Protein content of synovial fluid
The mean protein content of synovial fluid was 2.5 ± 0.2 mg/joint in the saline group. In the Avian-HA and Bio-HA groups it was higher, at 4.3 ± 0.1 and 4.6 ± 0.5 mg/joint, respectively, although the increase was not significant (Fig. 1). By contrast, the protein content in the Avian-CL-HA group was 7.9 ± 1.2 mg/joint, significantly higher than that in the saline, Avian-HA, and Bio-HA groups (parametric Tukey’s test, **P < 0.01 [vs. saline], †P = 0.01 [vs. Avian-HA], ¶P = 0.02 [vs. Bio-HA]).
Synovial fluid cell counts
In the Avian-HA and Bio-HA groups, three consecutive weekly injections did not induce a significant increase in any cell type in the synovial fluid (Fig. 2). In the Avian-CL-HA group, there was a significant increase in the average number of total cells (8.63 × 105), monocytes (5.95 × 105), and heterophils (1.22 × 105), compared to the saline group.
Tissue responses of normal rabbit knee joints to HA products
The histological appearance of the synovium is shown in Fig. 3. One day after three weekly injections of Avian-HA and Bio-HA, no histological changes were detectable in the synovium of treated animals when compared with that of the saline group. A slight proliferation of the synovial cells was seen after injections of Avian-HA and Bio-HA as well as saline; however, eosinophil infiltration was not observed. After three injections of Avian-CL-HA, marked stratification of synovial lining cells, prominent cellular infiltration including eosinophils, and edema in the synovial tissues were observed in all animals. Furthermore, aggregations of inflammatory cells were observed in three of the six animals treated with Avian-CL-HA (black arrowhead). Histological scores are shown in Fig. 4.
Protein content of HA products
To test whether our assays could efficiently recover protein from the HA products, we performed spike and recovery experiments in which a known amount of bovine serum albumin (BSA) was added to each HA product, and the protein content was determined thereafter. The recovery was close to 100%, ranging from 102 to 109%. As shown in Table 3, Avian-HA, Bio-HA, and Avian-CL-HA all had protein levels that were below the lower limit of quantification (< 10 μg/mL).
Table 3.
Product | Protein | Endotoxin | (1 → 3)-β-D-glucan |
---|---|---|---|
SUPARTZ FX™ (Avian-HA) | < 10 μg/mL | < 0.01 EU/mL | < 0.018 ng/mL |
ORTHOVISC® (Bio-HA) | < 10 μg/mL | < 0.05 EU/mL | < 0.054 ng/mL |
SYNVISC® (Avian-CL-HA) | < 10 μg/mL | < 0.05 EU/mL | 3.4 ng/mL |
Bacterial endotoxin test
Spike and recovery experiments were performed to determine the accuracy of the method. Recovery rate varied between 76% (Bio-HA) and 151% (Avian-CL-HA). As shown in Table 3, all the HA products had endotoxin levels that were below the lower limit of quantification (< 0.05 EU/mL; except for Avian-HA, < 0.01 EU/mL).
(1 → 3)-β-D-glucan content of HA products
Spike and recovery experiments were performed to determine the accuracy of the method. Recovery rates varied between 81% (Avian-HA) and 111% (Avian-CL-HA). As shown in Table 3, Avian-HA and Bio-HA had (1 → 3)-β-D-glucan levels that were below the lower limit of quantification (< 0.018 ng/mL and < 0.054 ng/mL, respectively). However, Avian-CL-HA contained 3.4 ng/mL (1 → 3)-β-D-glucan. To confirm the specificity of the test, Avian-CL-HA (100 μL) diluted 100-fold with water certified free of interfering glucan was mixed with 5 μL of 1.17 U/mL endo-(1 → 3)-β-D-glucanase and incubated at 37 °C for 1 h. As a result, 94.0% of the glucan signal was lost, confirming that the measured value for Avian-CL-HA was derived from (1 → 3)-β-D-glucan.
Discussion
In the present study, we selected three multiple-injection IA-HA products for evaluation which are highly prescribed globally. SYNVISC®, which has a unique safety concern as it causes rare pseudoseptic reactions, is a cross-linked HA derived from rooster comb (Avian-CL-HA). SUPARTZ FX™ and ORTHOVISC® were selected as representative products containing natural HA, derived from rooster comb (Avian-HA) and biological fermentation (Bio-HA), respectively.
In the knee joints of rabbits, Avian-HA and Bio-HA showed favorable biocompatibility compared with Avian-CL-HA. In the Avian-HA and Bio-HA groups, no increase in protein levels was observed in synovial fluid after administration of the products. As for the cell counts in synovial fluid, the patterns of cell recruitment in Avian-HA- and Bio-HA-treated animals were similar to those of the saline group. In the histological examinations, proliferative changes in the synovial surface layer were observed in both groups, but no significant changes were observed as compared with those in the saline-treated group, indicating that they were physiological reactions to the injection stimuli. These results suggest that biocompatibility of Avian-HA is comparable to Bio-HA. However, intra-articularly administered Avian-CL-HA induced severe inflammatory reactions accompanied by monocyte and heterophil infiltration and a significant increase in the number of cells in the synovial fluid. Histologically, aggregation of inflammatory cells, including eosinophils, was observed in the synovium of three animals out of six.
In a previous study, Schiavinato et al. assessed the biocompatibility of the avian-derived HA products, HYALGAN® and ARTZ® (also known as SUPARTZ FX™), in a rabbit model similar to that used in this study. They demonstrated that neither of these HA products increased the number of infiltrating inflammatory cells in synovial fluid [20]. Our previous study showed that intra-articular injection of hylan G-F 20 (SYNVISC®) into rabbit knee joints induced granulomatous inflammation, eosinophil infiltration, and a significant increase in the number of cells in the synovial fluid [19]. The present findings were similar to those previous results. Taken together, these studies show that SYNVISC® has a unique safety concern associated with immunostimulation, whereas there is no difference between Avian-HA and Bio-HA biocompatibility. Therefore, the pseudoseptic reactions reported in case reports on SYNVISC® might not be caused by the source of HA.
SYNVISC® is composed of 80% (v/v) hylan fluid (hylan A) and 20% (v/v) hylan gel (hylan B). SYNVISC® has a unique cross-linked structure in which hylan A has protein-mediated cross-linking and hylan B has additional DVS-mediated cross-linking. The histological examinations in several case reports on SYNVISC® show the development of granulomatous inflammation encompassing the hylan polymer in the knee joint, a typical histopathological observation for pseudoseptic reactions. It has been suggested that the low biodegradability of hylan polymer may be associated with the development of granulomatous inflammation [13, 14, 21]. In addition, our previous animal study revealed that another Avian-CL-HA product, GEL-ONE®, which has a cross-linking structure via cinnamic acid, showed more favorable biocompatibility and less immunogenicity compared to SYNVISC® [19]. These results support an association between the unique cross-linking structure and the unique safety concern for SYNVISC®.
Another factor related to safety is the presence of impurities in IA-HA products. In the present study, the levels of protein were below the lower limit of quantification in all the tested HA products (< 10 μg/mL). Regarding residual endotoxin levels, the previous study reported that SYNVISC® and ARTZ® contained 0.19915 ± 0.0741 and 0.0045 ± 0.0001 EU/mL of endotoxins, respectively [22]. Our study showed that the endotoxin levels in all products were below the lower limit of quantification (0.01–0.05 EU/mL: the differences in the lower limit of quantification were due to the differences in the test sample dilutions). We speculate that the discrepancies between the two studies may result from a difference in the endotoxin quantitation methods used and/or a decrease in the amount of impurities in the product. In the previous study [22], the Toxicolor™ system LS-50 M kit (Seikagaku Corporation) was used for measuring endotoxin in HA products. However, the Toxicolor™ system LS-50 M kit contains a serine protease zymogen factor G, which directly reacts with (1 → 3)-β-D-glucan, in addition to a lipopolysaccharide (LPS)-sensitive serine protease zymogen factor C [23]. Therefore, if (1 → 3)-β-D-glucan is present in the sample, the kit will detect it, giving a false-positive reading for endotoxins. In this study, we used Pyrochrome® plus Glucashield® buffer kit in which the specificity for endotoxin is greatly improved. It is reactive only to endotoxin, not to (1 → 3)-β-D-glucan [24]. Thus, Ohshima et al. may have detected the presence of (1 → 3)-β-D-glucan, rather than endotoxin contamination, in SYNVISC®.
(1 → 3)-β-D-glucan is a polysaccharide composed of D-glucose monomers linked by (1 → 3) beta-glycosidic bonds. It is a characteristic fungal cell wall constituent. It has been reported that fungi-derived (1 → 3)-β-D-glucan modulates various aspects of immunity [25–28]. Aside from fungi, dialysis membranes and filters made from cellulose are occasionally reported to contain (1 → 3)-β-D-glucan that may be solubilized during use. Therefore, the use of cellulose membranes during the manufacturing process is reported to result in significant increases of (1 → 3)-β-D-glucan in pharmaceutical products [29, 30]. In fact, the use of specific immunoglobulin products [31], cotton gauze, and sponges in surgeries [32] are reported to increase serum (1 → 3)-β-D-glucan levels. This is in addition to some drugs having a (1 → 3)-β-D-glucan formulation (lentinan, crestin, scleroglucan, and schizophyllan). Health risks associated with (1 → 3)-β-D-glucan contamination in pharmaceutical products were discussed at the Parenteral Drug Association annual meeting in 2017. Currently, endotoxin levels are strongly regulated and strictly tested for pharmaceutical products (ICH Q6A and Q6B Specifications, 1999 [33, 34]). However, little is known about the clinical significance of (1 → 3)-β-D-glucan contamination, and considerable uncertainty exists over the level at which immunostimulation may occur. Thus, there are no guidelines available on acceptable levels of (1 → 3)-β-D-glucan. In our study, only Avian-CL-HA, containing (1 → 3)-β-D-glucan, induced an increase in inflammatory cells and protein in synovial fluid, and the aggregation of inflammatory cells in the synovium. Although the possibility still remains that the specific structure of the cross-linking causes the inflammatory reactions, the present results suggest another possibility, which is that (1 → 3)-β-D-glucan in intra-articularly injectable preparations may trigger an inflammatory response. It may be safer to monitor the concentration of (1 → 3)-β-D-glucan included in IA-HA products.
The present study clearly demonstrates that Avian-CL-HA contains a high level of (1 → 3)-β-D-glucan contamination and suggests a possible link between this and the inflammatory response. Although the mechanism of pseudoseptic reactions following repeated SYNVISC® injections has not yet been elucidated, the reactions may not be caused by an avian-derived protein, but instead may be due to (1 → 3)-β-D-glucan content, the cross-linking structure in Avian-CL-HA, or both of these factors.
The limitation of this study was that we could not directly refer to the treatment of symptomatic knee OA because the findings were derived from an animal study. Additionally, it was not clear what caused the inflammatory response after Avian-CL-HA administration. Future research should focus on assessing the biocompatibility of extracted (1 → 3)-β-D-glucan from Avian-CL-HA. Furthermore, analyzing the correlation between the protein-mediated cross-linking structure and its biocompatibility may be useful in clarifying the mechanism of the immunostimulatory activity of Avian-CL-HA. These findings will provide new insights into the safety characteristics of IA-HA products.
Conclusions
The present results clearly demonstrate that the biocompatibility of Avian-HA is comparable to that of Bio-HA. However, immunostimulatory activity was observed after injection of Avian-CL-HA: this might be a result of its unique cross-linking structure and/or the considerable amount of (1 → 3)-β-D-glucan impurity present in the formulation.
Acknowledgments
We thank Dr. Tetsuya Ohtaki for reading and revising this manuscript, Mr. Kenji Miyamoto and Dr. Jun Aketagawa for suggesting the topic studied in this paper, Dr. Aisuke Nii for interpreting the histological appearance of the tissue sections, and Ms. Shuri Kajiwara, Ms. Haruka Mochizuki, and Mr. Hiroki Mitsushio for considerable technical assistance in this study.
Abbreviations
- Avian-CL-HA
SYNVISC®, a high molecular weight cross-linked hyaluronan derived from rooster comb
- Avian-HA
SUPARTZ FX™, a medium range molecular weight HA derived from rooster comb
- Bio-HA
ORTHOVISC®, a high range molecular weight HA obtained through biological fermentation
- H&E
Hematoxylin and eosin
- HA
Hyaluronic acid
- IA
Intra-articular
- OA
Osteoarthritis
Authors’ contributions
KY: study conception and design, acquisition of data, interpretation of data, drafting and revising the article, and final approval of the article to be published. MK: acquisition of data, interpretation of data, and final approval of the article to be published. TN: acquisition of data, interpretation of data, and final approval of the article to be published. KH, PhD: acquisition of data, interpretation of data, and final approval of the article to be published. ST, PhD: study conception, interpretation of data, and final approval of the article to be published. YK, PhD: study conception, interpretation of data, drafting and revising the article, and final approval of the article to be published. All authors have read and approved the manuscript.
Funding
No specific funding was received.
Availability of data and materials
The dataset supporting the conclusions of this article is stored in Seikagaku Corporation, Tokyo, Japan. Further inquiries on the data may be submitted to Keiji Yoshioka (keiji.yoshioka@seikagaku.co.jp).
Ethics approval and consent to participate
The animal studies were reviewed and approved by the Institutional Animal Care and Use Committee of Seikagaku Corporation and performed under the animal husbandry/management system in an appropriate environment, with animal protection/welfare in mind.
Consent for publication
Not applicable.
Competing interests
K. Yoshioka, M. Katayama, T. Nishiyama, K. Harada, S. Takeshita, and Y. Kawamata are employees of the Seikagaku Corporation.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Keiji Yoshioka, Phone: 81-42-563-5811, Email: keiji.yoshioka@seikagaku.co.jp.
Madoka Katayama, Email: madoka.katayama@seikagaku.co.jp.
Takeo Nishiyama, Email: takeo.nishiyama@seikagaku.co.jp.
Kohei Harada, Email: kohei.harada@seikagaku.co.jp.
Sawako Takeshita, Email: sawako.takeshita@seikagaku.co.jp.
Yuji Kawamata, Email: yuji.kawamata@seikagaku.co.jp.
References
- 1.Buckwalter JA, Saltzman C, Brown T. The impact of osteoarthritis: implications for research. Clin Orthop Relat Res. 2004;427:S6–15. doi: 10.1097/01.blo.0000143938.30681.9d. [DOI] [PubMed] [Google Scholar]
- 2.Vos T, Flaxman AD, Naghavi M, Lozano R, Michaud C, Ezzati M, et al. Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990–2010: a systematic analysis for the global burden of disease study 2010. Lancet. 2012;380:2163–2196. doi: 10.1016/S0140-6736(12)61729-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Felson DT. An update on the pathogenesis and epidemiology of osteoarthritis. Radiol Clin N Am. 2004;42:1–9. doi: 10.1016/S0033-8389(03)00161-1. [DOI] [PubMed] [Google Scholar]
- 4.Garstang SV, Stitik TP. Osteoarthritis: epidemiology, risk factors, and pathophysiology. Am J Phys Med Rehabil. 2006;85(Suppl 11):S2–S14. doi: 10.1097/01.phm.0000245568.69434.1a. [DOI] [PubMed] [Google Scholar]
- 5.Zhang W, Moskowitz RW, Nuki G, Abramson S, Altman RD, Arden N, et al. OARSI recommendations for the management of hip and knee osteoarthritis, part II: OARSI evidence-based, expert consensus guidelines. Osteoarthr Cartil. 2008;16:137–162. doi: 10.1016/j.joca.2007.12.013. [DOI] [PubMed] [Google Scholar]
- 6.Zhang W, Nuki G, Moskowitz RW, Abramson S, Altman RD, Arden NK, et al. OARSI recommendations for the management of hip and knee osteoarthritis part III: changes in evidence following systematic cumulative update of research published through January 2009. Osteoarthr Cartil. 2010;18:476–499. doi: 10.1016/j.joca.2010.01.013. [DOI] [PubMed] [Google Scholar]
- 7.Recommendations for the medical management of osteoarthritis of the hip and knee: 2000 update American College of Rheumatology Subcommittee on Osteoarthritis Guidelines. Arthritis Rheum. 2000;43:1905–1915. doi: 10.1002/1529-0131(200009)43:9<1905::AID-ANR1>3.0.CO;2-P. [DOI] [PubMed] [Google Scholar]
- 8.Hayes Anthony J., Melrose James. Glycosaminoglycan and Proteoglycan Biotherapeutics in Articular Cartilage Protection and Repair Strategies: Novel Approaches to Visco‐supplementation in Orthobiologics. Advanced Therapeutics. 2019;2(8):1900034. doi: 10.1002/adtp.201900034. [DOI] [Google Scholar]
- 9.Ogston AG, Stanier JE. The physiological function of hyaluronic acid in synovial fluid; viscous, elastic and lubricant properties. J Physiol. 1953;119:244–252. doi: 10.1113/jphysiol.1953.sp004842. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Altman RD, Dasa V, Takeuchi J. Review of the mechanism of action for Supartz FX in knee osteoarthritis. Cartilage. 2018;9:11–20. doi: 10.1177/1947603516684588. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Larsen NE, Dursema HD, Pollak CT, Skrabut EM. Clearance kinetics of a hylan-based viscosupplement after intra-articular and intravenous administration in animal models. J Biomed Mater Res B Appl Biomater. 2012;100:457–462. doi: 10.1002/jbm.b.31971. [DOI] [PubMed] [Google Scholar]
- 12.Goldberg VM, Coutts RD. Pseudoseptic reactions to hylan viscosupplementation: diagnosis and treatment. Clin Orthop Relat Res. 2004;419:130–137. doi: 10.1097/00003086-200402000-00021. [DOI] [PubMed] [Google Scholar]
- 13.Chen AL, Desai P, Adler EM, Di Cesare PE. Granulomatous inflammation after Hylan G-F 20 viscosupplementation of the knee: a report of six cases. J Bone Joint Surg Am. 2002;84-A(7):1142–1147. doi: 10.2106/00004623-200207000-00008. [DOI] [PubMed] [Google Scholar]
- 14.Michou L, Job-Deslandre C, de Pinieux G, Kahan A. Granulomatous synovitis after intraarticular Hylan GF-20. A report of two cases. Joint Bone Spine. 2004;71:438–440. doi: 10.1016/j.jbspin.2003.09.006. [DOI] [PubMed] [Google Scholar]
- 15.Waddell DD, Bricker DC. Hylan G-F 20 tolerability with repeat treatment in a large orthopedic practice: a retrospective review. J Surg Orthop Adv. 2006;15:53–59. [PubMed] [Google Scholar]
- 16.Puttick MP, Wade JP, Chalmers A, Connell DG, Rangno KK. Acute local reactions after intraarticular hylan for osteoarthritis of the knee. J Rheumatol. 1995;22:1311–1314. [PubMed] [Google Scholar]
- 17.Altman RD, Bedi A, Karlsson J, Sancheti P, Schemitsch E. Product differences in intra-articular hyaluronic acids for osteoarthritis of the knee. Am J Sports Med. 2016;44:2158–2165. doi: 10.1177/0363546515609599. [DOI] [PubMed] [Google Scholar]
- 18.Tanaka S, Aketagawa J, Takahashi S, Shibata Y, Tsumuraya Y, Hashimoto Y. Activation of a limulus coagulation factor G by (1→3)-β-D-glucan. Carbohydr Res. 1991;218:167–174. doi: 10.1016/0008-6215(91)84095-V. [DOI] [PubMed] [Google Scholar]
- 19.Ishikawa M, Yoshioka K, Urano K, Tanaka Y, Hatanaka T, Nii A. Biocompatibility of cross-linked hyaluronate (Gel-200) for the treatment of knee osteoarthritis. Osteoarthr Cartil. 2014;22:1902–1909. doi: 10.1016/j.joca.2014.08.002. [DOI] [PubMed] [Google Scholar]
- 20.Schiavinato A, Finesso M, Cortivo R, Abatangelo G. Comparison of the effects of intra-articular injections of Hyaluronan and its chemically cross-linked derivative (Hylan G-F20) in normal rabbit knee joints. Clin Exp Rheumatol. 2002;20:445–454. [PubMed] [Google Scholar]
- 21.Zerdawi IM, Chan I. Synvisc perisynovitis. Pathology. 2001;33:519–520. doi: 10.1080/00313020120083296. [DOI] [PubMed] [Google Scholar]
- 22.Ohshima Y, Yokota S, Kasama K, Ono H. Comparative studies of levels of proteins, bacterial endotoxins and nucleic acids in hyaluronan preparations used to treat osteoarthritis of the knee: could residual proteins and bacterial endotoxins relate to complications? Jpn Pharmacol Ther. 2004;32:655–662. [Google Scholar]
- 23.Toxicolor™ LS-50M kit package insert. http://www.lalbiz.com/common/frame/plugins/fileUD/download.php?type=attached_pdf&p=020130.pdf&token=2dc929c2c54cafd7e544e5f8f347f193177542c0&t=20181005092439. Accessed 09 Sept 2019.
- 24.Glucatell package insert. http://www.acciusa.com/pdfs/accProduct/pisheets/Glucatell%20Insert%20English.pdf. Accessed 09 Sept 2019.
- 25.Williams D, Mueller A, Browder W. Preclinical and clinical evaluation of carbohydrate immunopharmaceuticals in the prevention of sepsis and septic sequelae. J Endotoxin Res. 1995;2:203–208. doi: 10.1177/096805199500200309. [DOI] [Google Scholar]
- 26.Williams DL, Pretus HA, McNamee RB, Jones EL, Ensley HE, Browder IW, et al. Development, physicochemical characterization and preclinical efficacy evaluation of a water soluble glucan sulfate derived from Saccharomyces cerevisiae. Immunopharmacology. 1991;22:139–156. doi: 10.1016/0162-3109(91)90039-2. [DOI] [PubMed] [Google Scholar]
- 27.Browder W, Williams D, Pretus H, Olivero G, Enrichens F, Mao P, et al. Beneficial effect of enhanced macrophage function in the trauma patient. Ann Surg. 1990;211:605–613. [PMC free article] [PubMed] [Google Scholar]
- 28.Williams D, Browder W. Development of natural product (1→3)-β-D-glucan polymers as immune stimulating pharmaceuticals. Polymer Adv Tech. 1994;5:529–534. doi: 10.1002/pat.1994.220050910. [DOI] [Google Scholar]
- 29.Barton C, Vigor K, Scott R, Jones P, Lentfer H, Bax HJ, et al. Beta-glucan contamination of pharmaceutical products: how much should we accept? Cancer Immunol Immunother. 2016;65:1289–1301. doi: 10.1007/s00262-016-1875-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Sandle T. Pharmaceutical product impurities: considering beta glucans. Am Pharm Rev. Posted 31 August, 2013. http://www.americanpharmaceuticalreview.com/Featured-Articles/152953-Pharmaceutical-Product-Impurities-Considering-Beta-Glucans/. Accessed 09 Sept 2019.
- 31.Nakao A, Yasui M, Kawagoe T, Tamura H, Tanaka S, Takagi H. False-positive endotoxemia derives from gauze glucan after hepatectomy for hepatocellular carcinoma with cirrhosis. Hepatogastroenterology. 1997;44:1413–1418. [PubMed] [Google Scholar]
- 32.Usami M, Ohata A, Horiuchi T, Nagasawa K, Wakabayashi T, Tanaka S. Positive (1→3)-beta-D-glucan in blood components and release of (1→3)-beta-D-glucan from depth-type membrane filters for blood processing. Transfusion. 2002;42:1189–1195. doi: 10.1046/j.1537-2995.2002.00162.x. [DOI] [PubMed] [Google Scholar]
- 33.ICH Q6A specifications: test procedures and acceptance criteria for new drug substances and new drug products: chemical substances, October 1999. http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/Q6A/Step4/Q6Astep4.pdf. Accessed 7 Sept 2018. [PubMed]
- 34.ICH Q6B specifications: test procedures and acceptance criteria for biotechnological/biological products, March 1999. http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/Q6B/Step4/Q6B_Guideline.pdf. Accessed 7 Sept 2018.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The dataset supporting the conclusions of this article is stored in Seikagaku Corporation, Tokyo, Japan. Further inquiries on the data may be submitted to Keiji Yoshioka (keiji.yoshioka@seikagaku.co.jp).