Skip to main content
. 2003 Aug 6;23(18):7143–7154. doi: 10.1523/JNEUROSCI.23-18-07143.2003

Figure 7.

Figure 7.

MTII depolarized MC4-R/GFP neurons in a hypothalamic slice preparation. Whole-cell recordings were performed on MC4-R/GFP neurons held in current clamp. A sample recording from an MC4-R neuron treated with 100 nm MTII is shown. Mean effect: 2.47 ± 1.17 mV; n = 14; p = 0.028.