TABLE I.
Description | Parameter |
---|---|
X-ray energy | 4 keV–15 keV |
XFEL beam size at the interaction point | >1 μma or >1.5 μmb |
XFEL intensity per pulse (monochromatic beam) | ∼10 μJ at 10 keVc |
XFEL intensity per pulse (pink beam) | ∼600 μJ at 10 keVd |
XFEL pulse duration | <10 fs |
Optical wavelength | 200 nm–2000 nm |
Optical pulse duration (800 nm, full width at half-maximum; FWHM) | 30 fs |
Achievable time resolution (FWHM) | 70 fse |
Bragg angle range of Von Hamos spectrometers | 60°–75° |
Maximum momentum transfer (Q) available for TR-XDS (10 keV, 15 keV) | 3.88 Å−1, 5.82 Å−1 |
This corresponds to the focal beam size obtained with the Kirkpatrick-Baez (KB) mirrors.32
This corresponds to the focal beam size obtained with the CRLs.21
XFEL intensity after the four-bounced Si(111) reflections by the double channel-cut crystal monochromator21 implemented at SACLA BL3.
This is the typical case of SACLA BL3.
The time resolution depends on the optical pulse duration, the jet thickness, and other experimental conditions. This value was evaluated in Ref. 16.