. 2019 Sep 13;8(5):13. doi: 10.1167/tvst.8.5.13

Table 1.

The RGB Values Used in the PeekCS Testa

Score Stage
Optotype Gray RGB Value
Background Gray RGB Value
Actual Peek CS Log10 (CS)
Standard Error
Pelli-Robson Log10 (CS)
Contrast
1 0 255 0.006 0.000007 0.00 Highest
2 164 255 0.20 0.00040 0.15 E
3 197 254 0.35 0.000625 0.30
4 216 255 0.50 0.00026 0.45
5 229 255 0.65 0.001225 0.60
6 237 255 0.78 0.00306 0.75
7 242 254 0.96 0.00208 0.90
8 246 255 1.06 0.03935 1.05
9 248 255 1.16 0.0017 1.20
10 250 254 1.40 0.01185 1.35
11 250 253 1.53 0.0184 1.50
12 252 255 1.67 0.00475 1.65
13 246 248 1.71 0.00875 1.80
14 252 254 1.94 0.0034 1.95
15 254 255 2.00 0.0076 2.10 E
16 N/A N/A N/A N/A 2.25 Lowest

N/A, not applicable; RGB, red, green, blue.

a

Designed for a Sony Xperia Z3 for each Score Stage and the corresponding actual CS measured by a photometer in a darkened laboratory setting. Owing to the finite combinations of optotype and background grays, it is not possible to have an exact alignment between the contrast sensitivities tested with PeekCS and the Pelli-Robson charts. However, the difference between the two tests is never more than two-thirds of the difference between score stages (i.e., 0.10 log units).