Skip to main content
. Author manuscript; available in PMC: 2019 Sep 13.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2018 Jul 10;102(3):527–535. doi: 10.1016/j.ijrobp.2018.06.400

Table 2.

Spine radiosurgery (special case)

Organ at risk Dose constraint Margin Rank
Three fractions (prior radiation therapy <50 Gy)
 Cord 13.5 Gy 10% 1
 Esophagus 15 Gy max pt 0 mm 1
Single fraction
 Cord 10 Gy 10% 1
 Esophagus 15 Gy 2 cm3 0 mm 1
 Esophagus 20 Gy 2 cm3 3 mm 2