Nucleus detection (mean ± standard deviation) over the 23 datasets in terms of precision, recall, F1 score, and Euclidean distance

Precision (%) Recall (%) F1 score (%) Euclidean Distance
FCN 79.7 ±6.4 74.0 ±8.2 76.4 ±5.7 5.05 ±0.92
U-Net 83.0 ±6.6 71.7 ±7.0 76.6 ±4.5 6.01 ±0.72
FCRNA 73.7 ±8.3 86.6 ±6.8 79.3 ±5.4 4.12 ±0.84
FCRNB 68.6 ±9.4 87.5 ±6.8 76.5 ±6.9 4.36 ±1.19
FRCN 75.4 ±6.4 88.2 ±3.8 81.2 ±4.5 5.17 ±0.52
MicroNet 76.7 ±7.5 87.8 ±4.6 81.6 ±4.9 3.49 ±1.04