Assessments phase 2

Assessment variable Method Instrument used Validation
Weight In kg Digital weighing scale KRUPS co. 2016
Pre and post
Retd. design no. 161856
Waist circumference In cm Measuring tape
Pre and post
Blood pressure MmHg Digital sphygmomanometer Omron co. 2016 Model HEM7120
Questionnaires Details in app SES Int J Recent Trends Sci Technol 2014;11:1-2.
Kuppuswamy’s SES scale revised for 2014
Income and expenditure
Gururaj and Maheshwaran, 2014
Monthly for, individual and family
Sleep Quantity, quality, and sleep routine Pre-post Prepared for the purpose by our team
Quality of life PHQ
Stress PSS
6 NAS for work, family, health, others, social, financial related stresses NAS
Physical activity Typical daily work/home activity level, frequency and amount of mild, moderate, and vigorous activities
Substance abuse Alcohol - quantity, frequency and duration, tobacco - smokeless and smoked
Yoga related Yoga awareness (Nayak et al. 2014) Modified for the present Indian study[24]
Yoga benefit scale (Nayak et al. 2014) Modified for the present Indian study[24]
Yoga barrier scale (Nayak et al. 2014) Modified for the present Indian study[24]
Blood tests FBG>8 h after last meal Glucose oxidase-peroxidase method “Mindray” autoanalyzer Model no. BS - 390
PPBG 2 h after breakfast Glucose oxidase-peroxidase method “Mindray” autoanalyzer Model no. BS - 390
HbA1c Fasting sample High-pressure liquid chromatography using the Variant™ II Turbo machine (Bio-Rad, Hercules, CA, USA) National Glycohemoglobin Standardization Program
Total cholesterol Cholesterol esterase oxidase- peroxidase-amidopyrine Auto-analyzer model 2700/480 Beckman Coulter®
Triglycerides Glycerol phosphate oxidase- peroxidase-amidopyrine Auto-analyzer- model 2700/480 Beckman Coulter
Low-density lipoprotein Serum Auto-analyzer-model 2700/480 Beckman Coulter
Very low-density lipoprotein Serum Auto-analyzer-model 2700/480 Beckman Coulter
High-density lipoprotein Polyethylene glycol-pretreated enzymes Auto-analyzer-model 2700/480 Beckman Coulter

SES=Socioeconomic status, NAS=Numerical Analog Scale, HbA1c=Hemoglobin A1c, PSS=Perceived stress scale, PHQ=Patient health questionnaire, PPBG=Postprandial blood glucose, FBG=Fasting blood glucose