TABLE 1.

PARAMETERS FOR DIFFUSION-TYPE HOLES (P/D=6. L/D=12, RE=11000. DR=1.051)

Hole Geometry Nominal Blowing Ratio Coolant Exit Temperature (°F) Freestream Recovery Temperature (°F) Uncertainty in η (%) Uncertainty (°F)
Fluidic 1 51.4 74.9 0.2 0.05
Fluidic 1.5 50.5 75.2 0.2 0.05
Fluidic 2 48.6 74.6 0.2 0.05
Fluidic 2.5 47.6 75.0 0.2 0.05
777 1 53 75.4 0.2 0.05
777 1.5 52.4 75.5 0.2 0.05
777 2 50.9 74.6 0.2 0.05
777 2.5 50.3 75.4 0.2 0.05
Square 1 53.9 72.2 1.1 0.2
Square 1.5 52.5 72.3 1.0 0.2
Square 2 50.2 72.2 0.9 0.2
Square 2.5 53.5 74.9 0.9 0.2