Skip to main content
. Author manuscript; available in PMC: 2020 Oct 1.
Published in final edited form as: Biomaterials. 2019 Jul 15;219:119363. doi: 10.1016/j.biomaterials.2019.119363

Fig. 6: Therapeutic applications enhanced with variable patterning.

Fig. 6:

A) Variable frequency trains in functional electrical stimulators (FES) can support improved gait [reproduced with permission from46]. B) Chaotic pacing was more effective at stabilizing random arrhythmias than periodic pacing. Y-axis indicates beat-to-beat intervals and x-axis indicates beat number. Start and end positions of chaotic control and periodic control are indicated [reproduced with permission from206]. C) Respiratory sinus arrhythmia (RSA) is an important component of normal breathing, where heart rate increases with inspiration and decreases with expiration, and is associated with ventilation/perfusion matching. Fractal ventilation (FV) patterns in a study of mechanical ventilators was shown to increase RSA compared to conventional ventilation (CV) [reproduced with permission from64].