Skip to main content
. 2019 Sep 24;9:13750. doi: 10.1038/s41598-019-50251-8

Table 2.

Summarized results of the evaluation of the segmentation methodology for the thrombus on a data set of 40 CT-scan obtained from patients with infrarenal AAA.

Segmentation of the thrombus (525 slices analyzed)
Mean+/−SD Min- Max Median Interquartile range
Surface from manual method (mm2) 1109.9 +/− 685.7 206.2–3359.1 924.8 538.8–1589.1
Surface from automatic method (mm2) 1149.0 +/− 665.3 202.2–3088.0 1034.5 556.5–1627.4
Volume similarity 0.91 +/− 0.11 0.40–1.00 0.95 0.90–0.98
Sensitivity 0.91 +/− 0.14 0.22–1.00 0.96 0.91–0.99
Specificity 0.9978 +/− 0.0029 0.9778–1.0000 0.9988 0.9974–0.9993
Jaccard index 0.80 +/− 0.15 0.12–0.96 0.85 0.78–0.89
Dice Similarity Coefficient 0.88 +/− 0.12 0.22–0.98 0.92 0.87–0.94
Hausdorff distance 2.13 +/− 0.68 0.88–6.48 1.98 1.69–2.39